Basic Specifications

Display Block10.4-inch TFT color LCD
Effective screen area: 211.2 mm x 158.4 mm (640 dots x 480 dots)
Printer Block (RA1200/RA1300)
 Printing methodThermal printing using a thermal head
 Paper Width219.5 mm
 Effective Recording Width1 split (200mmFS) to 16 splits (10mmFS), Number ofsplit and
printing width can be changed.
 Channel DiscriminationPrints channel number in the vicinity of theprinted waveform
The ON/OFF function is available.
Battery BackupBackup Contents: Main unit settings,Recording conditions
Backup time: About 1 month (if fully charged and used under normaltemperature)
Storage DevicesA built-in 3.5-inch floppy disk drive(1.25MB/1.44MB)
PC card slot (ATA flash memory card, SRAM card)
Built-in MO unit (640, 540, 230, and 128MB supported): optional
InterfaceRS-232C unit (38400 to 2400 bps): optional
GP-IB unit (IEEE488 compliant): optional
SCSI unit (50-pin type): optional
Remote TerminalStart/stop, mark print, and paper feed areavailable by external signal,
synchronous pulse Input, protect input, output of waveformjudgement
results, and error output
Clock FunctionStability: Daily error within ±35 PPM (at normaltemperature)
Operating EnvironmentTemperature: 0 to 40°C (5 to 40°C whenFFD is operating)
Humidity: 35 to 80% RH (without condensation)
Vibration Resistance: MIL-STD-810E compliant (except when FD orMOis operating)
Power Supply90 to 132 VAC/180 to 264 VAC (to be specified whenordering)
Frequency 47 to 63Hz
DC power unit (optional) In use: 11 to 28 VDC(AC power isprioritized)
PowerConsumption(Maximum)RA1100: Approx. 85 VA
RA1200: Approx. 180 VA (About 85 VA during stand-by)
RA1300: Approx. 350 VA (About 85 VA during stand-by)
DimensionsApprox. 369.5 (W) x 150.5 (H) x 301(D)mm
WeightApprox. 6.6kg (RA1100 main unit withfour 2-ch high-resolution DC amps)
Approx. 7.5kg (RA1200 main unit with four 2-ch high-resolution DCamps)
Approx. 7.5 kg (RA1300 main unit with four 2-ch high-resolution DCamps)


 

Trigger Specifications

Trigger ModeOR, AND, A*B, WINDOW
Trigger SourceInput Signal, time trigger (startingtime, ending time, measurement
interval), manual trigger and external trigger
Trigger SettingAmps other than event amps
 Trigger SlopeOR, AND.....or
  A*B...orfor each A,B source
  WINDOW...OUT or IN
Level Setting: To be setwith physical values (e.g. voltage)
Event Amp
 State Settings:H, L, or OFF can be set for each input (withouttrigger
slope) When OFF is set, trigger condition is notapplied.
 Trigger Setting:AND or OR of the state settingconditions of inputs
from 1 to 8
Trigger Related FunctionsPre-trigger , trigger pass count,trigger filter, and trigger mark


Other Specifications

Print Functions(RA1200/RA1300)
 Data InformationMeasurement mode, year/month/day,Measurement start time, Data No.,
Trigger conditions (Trigger point, Trigger year/month/day, Triggertime),
Sampling speed, Chart speed, Time axis, etc. are printedsimultaneously
with waveform print). ON/OFF function is available.
Channel InformationInput unit settings are printedsimultaneously. ON/OFF function is available.
Mark printIn the real-time mode, the mark printis available (M date/time)
List Print.Date, time, measurement mode, data No., record form, chart speed,
sampling speed, scale printing, back-light auto-off, auto start,buzzer
click, trigger mode, source channel, recording operation, filingsetting printout
Screen Copy FunctionPrints hard copies of the contentsshown on the screen
A4 report outputRegisters free comments and prints themtogether with the waveform printing
Printing Line WidthSets baseline boldness (1, 2, 3, 4dots) for each channel
Key Lock FunctionInvalidates key input to preventerroneous operation
Storing and Readingof SettingsUp to four conditions for input unitand main unit settings are stored in
the main unit memory
Physical ValueConversionPhysical conversion of input signal,full-scale modification of display
Stand-by FunctionWhen the main unit is restored fromblackout or temporary halt, original
state is regained.(Except when filing)
Automatic SetupFunctionBy presetting a floppy disk containingthe measurement conditions in FD
drive, the conditions are automatically read when turning on thepower.
Storing the ScreenImageStores a screen image in bitmap formatinto a floppy disk
Help FunctionDisplays the handling method, cautions,etc.
RS-232C Unit Function
 Remote ControlControls the main unit from a personal computer viathe RS-232C cable.
FAX Transmission FunctionSends measured waveform by using a FAX modemconnected to RS-232C.
GB-IB Unit Function
 Remote ControlControls the main unit from a personal computer viaGB-IB cable.
SCSI Unit Function
 Stores data to MO or PD as external memorydevices.


 

AC Bridge Power Supply Unit (Optional)

FunctionBridge power source for 2-ch AC strainamp
Power Voltage, Carrier Wave2 Vms, Sine wave 5kHz
SynchronismSynchronization with other RA1000susing a built-in AC bridge power unit is available.


Memory Mode

Measurement OperationOnce, Repeat, Endless
Memory Capacity256kW/CH (Max.1 MW/CH optionallypossible)
*When function operation is used, memory capacity is 1/4
When two channels are used, 2MW/CH is the maximum
Memory Division1, 2, 4, 8, 16, 32, 64, and 128divisions
Sampling1 µs (1 MS/s) to 1 s(1 S/s),User-settableExternal synchronization enabled
Display (ReplayMonitor)
 Waveform DisplayDisplay magnification :x5 to x1/1000
X-Y DisplayX-Y display where data of an any channelis shown on the X axis, and
other channel on the Y axis. Display step: 1 to 1000 steps
Print (RA1200/RA1300)
 Waveform PrintPrint Density: Voltage axis: 8 dots/mmTime axis: 10 dots/mm
Copy magnification: x5 to x1/1000
Alphanumeric PrintReadout Interval : 1 to 1000 steps
X-Y PrintX–Y print where data of an any channelis shown on the X axis, and other
channel on the Y axis. Effective print range : 200 mm x 200 mmPrint
density : 400 dots (X axis) x 400 dots (Y axis) Display step : 1to 1000 steps
Memory FilingEach time data is stored into memory,the data is saved in the memory
device in the binary or CSV format.


Real-Time Mode (RA1200/RA1300)

Waveform Printing
 Measurement Starting OperationStarts with the Start key, by thetrigger detection, or at set time.
Interval recording available.
Paper Speed25 mm/s to 1 mm/sec (RA1200), 100 mm/sto 1 mm/min (RA1300),
User settable. External synchronization enabled
Frequency ResponseDC to 100 kHz (sampling points: 10points/cycle), Varies depending on the input units
Printing DensityVoltage axis : 8 dots/mm
Time axis:RA1200:10 dots/mm
 :RA1300:20 dots/mm at 100 mm/s
  :40 dots/mm at 50 mm/s
  :80 dots/mm at 25 mm/s
Printing LengthContinuous or 1 to 1000 division-shotfeeding
Alphanumeric Printing
 Sampling1 s to 1 hour, User settable, Externalsynchronization enabled
Printing Length SettingContinuous or 1 to 1000 data shot feeding
X-Y Printing
 PerformanceX-Y recording where data of an anychannel is shown on the X axis, and
other channel on the Y axis. Continuous recording until stopbutton is
pressed (pose function available)
Effective Printing Range200 mm x 200 mm
Printing Density400 dots (X axis) x 400 dots (Y axis)
Printing Speed10 ms or more
Backup FilingStores the measured data in a memorydevice in real-time
Recording Speed: Synchronized with paper speed


Transient Mode

Transient Recording(RA1200/RA1300)
 FunctionNormally operates in the real-time mode.When trigger is detected, the
mode is switched to the memory mode.
Real-time SectionIn conformance with the waveformprinting in the real-time mode
Memory SectionIn conformance with data storage andprinting in the memory mode
Transient Filing
 FunctionNormally operates in backup filing, datais saved in a memory when trigger is detected, and when measurementfinishes, the memory data is saved.
Real-Time SectionIn conformance with backup filing in the real-timemode
Memory SectionIn conformance with memory filing in thememory mode


Filing Mode

Data Recording
 FunctionStores the measured data real-time to amemory device (Real time filing)
Recording Speed200 µs to 60 s. Maximum recording speedvaries depending on number
of channels and recording device. User settable Externalsynchronization ennobled
Recording MethodSelect normal or ring
Ring recording is possible (Repeated recording during set time)
Waveform Printing(RA1200/RA1300)
 FunctionPrints the waveform of input signal
Paper Speed25 mm/s to 1 mm/m (RA1200), 100 mm/s to 1mm/m(RA1300) User
Settable External synchronization enabled
Frequency ResponseDC to 100 kHz (sampling point: 10points/cycle), Varies depending on
the input units
 Printing DensityVoltage axis : 8 dots/mm
Time axis:RA1200:10 dots/mm
 :RA1300:20 dots/mm at 100 mm/s
  :40 dots/mm at 50 mm/s
  :80 dots/mm at 25 mm/s


FFT Unit (Optional)

1 Signal AnalysisLinear spectrum, power spectrum, RMS spectrum,power spectrum
density, and octave analysis (1/1, 1/3)
2 Signals AnalysisTransfer function, coherence function,and cross-power spectrum
Window FunctionRectangular, hanning, hamming,exponential, force
Addition ProcessingSimple additional average (time axis),simple additional average
(frequency axis), exponential weighted average (frequency axis),and peak hold
Analysis Frequency400kHz, 200kHz, 80kHz, 40kHz, 20kHz,10kHz, 5kHz, 2kHz, 1kHz,
500Hz, 200Hz, 100Hz, 50Hz, 20Hz, and 10Hz
Resolution400 (1000), 800 (2000), 1600 (4000)
Numbers in parentheses indicates the number of samplingpoints.


Arithmetic Operation Unit (Optional)

Sectional StatisticalOperationMaximum value, minimum value, P-P value, averagevalue, area, effective value, standard deviation, rising time,falling time
Function OperationFour-function calculation, absolutevalue, differential, integration, secondary differential, doubleintegration, square root, exponential, common logarithm, movingaverage, and trigonometric functions (sin, cos,tan, asin, acos,atan)


Waveform Judgment Unit (Optional)

FunctionMeasures waveform of input signals of eightchannels, and outputs the results of waveform judgement
Targets of OutputtingResultsPrint on paper, FAX, data storage, orremote terminal output


2-CH High Resolution Amp (AP11-101)

Input2channels/unit, isolated unbalanced input, isolatedBNC connector
Input couplingAC and DC coupling
Input impedance1Mor higher
Measurement range0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50,100, 200, and 500 V
Range accuracyWithin 0.3% FS (Within 0.8% FS at 500V)
Offset accuracyWithin 0.3% FS (at 25°C)
LinearityWithin 0.1% FS
Allowable inputvoltageRange of 10 V to 500 V: 500 V max. (ACor DC peak values)
Range of 0.1 V to 5 V: 100 V max. (AC or DC peak values)
CMVUnit only: 43 V (AC or DC peakvalues)When using isolated BNC cable
(optional): 300 VAC
Frequency responseAt DC coupling: DC to 50 kHz (+0.5, -3dB)
At AC coupling: 0.3 to 50 kHz (+0.5, -3 dB)
Low-pass filterBessel type (attenuation factor: -12dB/OCT)
30, 300, 3 kHz, and OFF (+0.5, -3 dB)
A/D converter16 bits, 100 kHz max. (two channelsimultaneous sampling)
Temperature stabilityZero point: Within 0.03% FS/°C
Gain (range): Within 0.01% FS/°C
Weight230 g


2-CH High Speed Amp (AP11-103)

Input2channels/unit, isolated unbalanced input, isolatedBNC connector
Input couplingAC and DC coupling
Input impedance1Mor higher
Measurement range0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50,100, 200, and 500 V
Range accuracyWithin 0.5% FS (Within 0.8% FS at 500V)
Offset accuracyWithin 0.5% FS (at 25°C)
LinearityWithin 0.2% FS
Allowable inputvoltageRange of 10 V to 500 V: 500 V max. (ACor DC peak values)
Range of 0.1 V to 5 V: 100 V max. (AC or DC peak values)
CMVUnit only: 43 V (AC or DC peakvalues)When using isolated BNC cable
(optional): 300 VAC
Frequency responseAt DC coupling: DC to 400 kHz (+0.5, -3dB)
At AC coupling: 0.3 to 400 kHz (+0.5, -3 dB)
Low-pass filterBessel type (attenuation factor: -12dB/OCT)
50, 500, 5 kHz, and OFF (+0.5, -3 dB)
A/D converter12 bits, 1 MHz max. (two channelsimultaneous sampling)
Temperature stabilityZero point: Within 0.03% FS/°C
Gain (range): Within 0.01% FS/°C
Weight240 g


2-CH TC/DC Amp (AP11-106)

Input2channels/unit, isolated unbalanced input, terminalblock 4
Input couplingDC coupling
Input impedance10Mor higher
ThermocoupleR, T, J, K, and W
Measurement rangeR: 0 to 1600°C
T: -200 to 400°C
J: -200 to 1000°C
K: -200 to 1350°C
W: 0 to 2300°C
Voltage measurementrange100, 200, 500 mV, 1, 2, 5, 10, 20 and50 V FS
Range accuracyTemperature: Within 0.5% FS (Within 1%FS at 0°C or lower)
Voltage: Within 0.5% FS
Cold junctioncompensationInternal/external switchable
Accuracy: Within 2°C (Within 1°C at stable temperature of 20°C atinput terminal)
LinearityWithin 0.1% FS
Allowable inputvoltage50 V (AC or DC peak values)
CMV43 V (AC or DC peak values)
Frequency responseDC to 40 kHz (+0.5, -3 dB)
Low-pass filterBessel type (attenuation factor: -18dB/OCT) 1, 30, 500, 5 kHz, and OFF (+0.5, -3 dB)
A/D converter15 bits, 100 kHz max. (two channelsimultaneous sampling)
Temperature stabilityAccuracy: 0.04% FS/°C (When used astemperature amp)
Zero point: Within 0.03% FS/°C (When used as DC amp)
Gain (range): Within 0.01% FS/°C
Weight240 g


 

TC/DC Amp (AP11-107)

Input1 channel/unit, isolated unbalanced input, 2binding posts
Input couplingDC coupling
Input impedance10M or higher (1M at 5, 10, 20, 50 V FS in DC amp)
ThermocoupleR, T, J, K
Measurement rangeR: 0 to 800°C at 800°C FS and 0 to1600°C at 1600°C FS
T: -200 to 200°C at 200°C FS and -200 to 400°C at 400°CFS
J: -200 to 200°C at 200°C FS and -200 to 1000°C at 1000°C
K: -200 to 200°C at 200°C FS and -200 to 1200°C at 1200°C
Voltage measurementrange10, 20, 50, 100, 200, 500 mV, 1, 2, 5,10, 20, and 50 V FS
Range accuracyTemperature: Within 0.5% FS (Within 1%FS at 0°C or lower)
Voltage: Within 0.5% FS
LinearityWithin 0.1% FS
Allowable inputvoltage50 V (AC or DC peak values)
CMV300V (AC or DC peak values)
Frequency responseDC to 40 kHz (+0.5, -3 dB)
Low-pass filterBessel type (attenuation factor: -18dB/OCT) 1, 30, 500, 5 kHz, and OFF (+0.5, -3 dB)
Reference junctioncompensationInternal/external switchable
A/D converter14 bits, 100 kHz max.
Weight200 g


Event Amp (AP11-105)

Number of channels8 channels/unit
Input signalSets voltage or contact for eachchannel
Voltage input: Input voltage range 0 to +24 V
Detection levelH level...2.5 V or higher
 L level...0.5 V or lower
Contact input:Close...250 or lower
 Open...2 kor higher
Response time1µs or faster (Input level should be +5V or higher.)
Input connectorRound DIN connector 8P...2 pcs.
Event amp side: XT2B-0800(Conformed to DIN45326)
Weight100 g


 

2-CH AC Strain Amp (AP11-104)

Number of channels2 channels/unit, isolated balanced input, NDISconnector
Applicable gaugeresistance120to 1k
Bridge power supplySine wave 2 Vrms, 5 kHz (Bridge powersupply is supplied separately.)
Gauge factor1.9 to 2.2
Range of balanceResistance: 2% (10000 µ)or lower Capacitance: 2000 pF or lower
Balance methodResistance: Auto-balance
Capacitance: Auto-balance (500 pF or lower, eliminatingconstantly)
Balance time: Within 1s at 1 ch Within 0.5%Fs Remained voltageaccuracy
Maximum sensitivityOver full-scale at 500 µ(at 2 V or higher bridge voltage)
Measurement range1, 2, 5, 10, 20 kµFS
Internal calibratorand accuracy0.5 k, 1 k, 2 k, 3 k, 5 kµAccuracy: Within 0.5% FS
Linearity0.2% FS
CMV300 VAC
Frequency responseDC to 2 kHz (+0.5, -3dB)
Low-pass filterButterworth type (attenuation factor:-12 dB/OCT)
10, 30 , 100, 300 Hz, and OFF (+0.5, -3 dB)
A/D converter16 bits, 100 kHz max.
Temperature stabilityZero point: Within 0.05% FS/°C
Gain (range): Within 0.05% FS/°C
Weight285 g


 


2-CH DC Strain Amp (AP11-110)

Number of channels2 channels/unit, isolated balancedinput, NDIS connector
Input couplingDC
Input impedance10M+10Mor higher
Bridge power supply2 V and 5 V
Applicable gaugeresistance120 to 2 k (at BV = 2V),350 to 2k (at BV=5 V)
Gauge factor2
Range of balance2% (15000 µorlower
Balance methodResistance: Auto-balance
Balance time: 0.5 sec max. at 1ch
Remained voltage accuracy: Within 0.3% FS
Measurement range2, 5, 10, 20, 50 kµFS (at BV = 2 V)
0.8, 2, 4, 8, 20 kµFS(BV = 5 V)
Voltage measurementrange2, 5, 10, 20, 50 mV FS
Range accuracyWithin 0.3% FS
Linearity0.1% FS
Allowable inputvoltage8 V (DC or AC peak values)
Frequency responseDC to 50 kHz (+0.5, -3dB)
Low-pass filterBessel type (attenuation factor: -12dB/OCT)
10, 30, 300 Hz, 1 kHz, and OFF (+0.5, -3 dB)
Temperature stabilityZero point: Within 0.1% FS/°C
Gain (range): Within 0.01% FS/°C
CMV300 VAC
A/D converter16 bits, 100 kHz max
Weight240 g


2-CH Vibration/RMS Amp (AP11-109)

Input2 channels/unit, isolated unbalancedinput, isolated BNC connector
Input couplingAC and DC
Input impedance10 Morhigher
Power supply forsensor2 mA, 18 V or higher
Measurement range0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50,100, 200, 500 V
Range accuracyDC amp range: Within 0.3% FS (Within0.8% FS at 500 V)
RMS amp range: Within 2% FS (at DC and 40 Hz to 20 kHz)
LinearityWithin 0.1% FS
Crest factor2.8 max. (RMS amp)
CMVUnit only: 42 V (DC or AC peakvalues)
When isolated BNC cable (optional) is used: 300 V AC
Frequency responseDC coupling: DC to 50 kHz (+1, -3dB)
AC coupling: 1 to 50 kHz (+1, -3 dB)
Low-pass filterButterworth type (attenuation factor:-24 dB/OCT)
30, 100, 300 Hz, 1 kHz, and OFF
High-pass filterButterworth type (attenuation factor:-24 dB/OCT)
10, 30, 100 Hz, and OFF
A/D converter16 bits, 100 kHz max.
Temperature stabilityZero point: Within 0.02% FS/°C
Gain (range): Within 0.01% FS/°C
Weight270 g


 

2-CH FFT Amp (AP11-102)

Input2 channels/unit, isolated unbalancedinput, isolated BNC connector
Input couplingAC and DC (only AC coupling whenamp-embedded charge accelerometer is used)
Input impedance1 Mor higher
Power supply forsensor2 mA, 18 V or higher
Measurement range0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50,100, 200, 500 V
Range accuracyWithin 0.3% FS (Within 0.8% FS at 500V)
LinearityWithin 0.1% FS
Maximum input voltage500 V (DC or AC peak values) (30 V atAC coupling of 0.1 to 5 V)
CMVUnit only: 42 V (DC or AC peakvalues)
When isolated BNC cable (optional) is used: 300 V AC
Frequency responseDC coupling: DC to 50 kHz (+0.5, -3dB)
AC coupling: 0.3 to 50 kHz (+0.5, -3 dB)
Low-pass filterBessel type (attenuation factor: -24dB/OCT)
30, 300 Hz, 3 kHz, and OFF (+0.5, -3 dB)
Anti-aliasing filter20, 40, 80, 200, 400, 800 Hz, 2, 4, 8,20, and 40 kHz
Drop characteristic: -72 dB typ. at 1.5 x fc
Offset accuracyWithin 0.3% FS (at 25 °C)
A/D converter16 bits, 100 kHz max.
Temperature stabilityZero point: Within 0.02% FS/°C
Gain (range): Within 0.01% FS/°C
Weight240 g


 

F/V Converter (AP11-108)

Input1 channel/unit, isolated unbalancedinput, isolated BNC connector
Input couplingAC and DC
Input impedance100 M or higher
Input frequency range1 Hz to 10 kHz (Pulse width: 20 µs orlonger)
Measurement range0.1, 0.2, 0.5, 1, 2, 5, 10 kHz FS
Range accuracyWithin 0.5% FS (Within 0.8% FS at 500V)
LinearityWithin 0.3% FS
Trigger levelSelectable from 0 V and 2.5 V
Allowable inputvoltage100 V (AC or DC peak values)
CMVUnit only: 42 V (AC or DC peakvalues)
Between isolated BNC and safety terminal (optional): 300 VAC
Response timeApprox. 20 ms (at the range of 10 kHz)
A/D converter16 bits, 100 kHz max.
Temperature stabilityZero point: Within 0.03% FS/°C
Gain (range): Within 0.02% FS/°C
Weight240 g



Charge Converter (AP11-901)

Gain1.0 mV/pC ±5%
Max. input charge5000 pC
Frequency rangeApprox. 1.6 Hz to 50 kHz
Max. output voltage5 Vp-p or lower
Drive voltage12 to 25 VDC
Drive current0.5 to 5.0 mA
Rated noise20 µVrms or lower
Phase180°(Inverted input is output.)
Operating temperature-20 to 80°C
ConnectorInput: Miniature connector (10-32)
Output: Male BNC terminal
Weight20 g


 

Charge Converter (AP11-902)

Gain1.0 mV/pC ±5%
Max. input charge5000 pC
Frequency rangeApprox. 1.6 Hz to 50 kHz
Max. output voltage5 Vp-p or lower
Drive voltage12 to 25 VDC
Drive current0.5 to 5.0 mA
Rated noise20 µVrms or lower
Phase180°(Inverted input is output.)
Operating temperature-20 to 80°C
ConnectorInput: Miniature connector (10-32)
Output: Male BNC terminal
Weight65 g


 


Charge Converter (AP11-903)

Gain1.0 mV/pC ±5%
Max. input charge50000 pC
Frequency rangeApprox. 1.6 Hz to 50 kHz
Max. output voltage5 Vp-p or lower
Drive voltage12 to 25 VDC
Drive current0.5 to 5.0 mA
Rated noise20 µVrms or lower
Phase180°(Inverted input is output.)
Operating temperature-20 to 80°C
ConnectorInput: Miniature connector (10-32)
Output: Male BNC terminal
Weight65 g


 NameModelRating
Main unitOmniace IIRA1100Data acquisition system without printer
RA1200Data acquisition system with printer, paper speed:25 mm/s max.
RA1300Data acquisition system with printer, paper speed:100 mm/s max.
Standard accessoriesAC power cable x 1, Recording paper x 1(RA1200/1300), Paper holder x 1 (RA1200/1300), Slot cover plate forinput and interface units x 1 set, and user's manual x 1set


产品留言
标题
联系人
联系电话
内容
验证码
点击换一张
注:1.可以使用快捷键Alt+S或Ctrl+Enter发送信息!
2.如有必要,请您留下您的详细联系方式!


联系我们
产品目录
Copyright© 2003-2018 广东禾泰电子科技有限公司版权所有    地址:广东广州五羊新城东兴北路98号    邮编:510600
电话:电话1:020-29066604 电话2:020-33555331 电话3:13682257159 服务热线:4006-252-256    传真:020-61326626    粤ICP备18050318号-1  
 

粤公网安备44130202000622号